Control
System
When you have selected the row "System" press to enter
the sub menu . There are ten different systems to choose
between.
System selection can occur during 15 minutes after SCU 10
has been powered. It is not possible to change the system,
until the voltage is switched off and on it again.
System 1
Basic system with one tank, one pump, one solar panel and
two sensors. With this system you can choose to add extra
functions with one or two sensors (Thermostat, Cooling or
Diff. control function).
System
1
T1
T2
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
6\VWHP
Menu 2.1 [N] Set temp tank1Menu 2.0 [S] Settings
Menu 2.2 [N] dTStart tank1System 1
Menu 2.3 [N] dTStop tank1
System 2
Basic system with two tanks, one pump, one reversing valve,
one solar panel and three sensors.
System
2
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2 T4
6\VWHP
6\VWHP
Menu 2.1 [N] Set temp tank1Menu 2.0 [S] Settings
Menu 2.2 [N] dTStart tank1System 2
Menu 2.3 [N] dTStop tank1
Menu 2.4 [N] Set temp tank2
Menu 2.5 [N] dTStart tank2
Menu 2.6 [N] dTStop tank2
Menu 2.7 [N] Min rev pump
Menu 2.8 [N] Mintemp prio
tank
System 3
System with two tanks, two pumps, one solar panel and
three sensors.
System
3
T1
T1 _ _ _°C
T2 _ _ _ °C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
6\VWHP
6\VWHP
Menu 2.1 [N] Set temp tank1Menu 2.0 [S] Settings
Menu 2.2 [N] dTStart tank1System 3
Menu 2.3 [N] dTStop tank1
Menu 2.4 [N] Set temp tank2
Menu 2.5 [N] dTStart tank2
Menu 2.6 [N] dTStop tank2
Menu 2.7 [N] Min rev pump
Menu 2.8 [N] Mintemp prio
tank
System 4
System with one tank, one pump, one reversing valve, two
solar panels (east/west) and three sensors. With this system
you can use extra functions with one sensor (Thermostat or
Cooling function).
System
4
T1 T4
T2
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
6\VWHP
6\VWHP
Menu 2.1 [N] Set temp tank1Menu 2.0 [S] Settings
Menu 2.2 [N] dTStart tank1System 4
Menu 2.3 [N] dTStop tank1
System 5
System with one tank, two pumps, two solar panels
(east/west) and three sensors. With this system you can use
extra functions with one sensor (Thermostat or Cooling
function).
System
5
T1 T4
T2
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
6\VWHP
6\VWHP
Menu 2.1 [N] Set temp tank1Menu 2.0 [S] Settings
Menu 2.2 [N] dTStart tank1System 5
Menu 2.3 [N] dTStop tank1