EasyManua.ls Logo

Nibe SCU 10 - System Description Principle of Operation

Nibe SCU 10
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System description
Principle of operation
SCU 10 has been specially developed to work with NIBE's
heat pumps and existing heating and hot water equipment.
SCU 10 can be used with a number of different connection
options. With SCU 10 control the heat is spread from the
solar panel to the heat store, i.e. the accumulator and is
stored there when the sun is shining. The stored heat is then
distributed and used when the need arises.
-EP30-BT53
-EP8
-AA25
-EP30
-CM5
-GP4
-QM45
-RM3
-QM43
-QM44
-RM4
T
-GP30
T
-FL4
P
-CP1
-EP30-BT54
Pump station SPS 10 / SPS 20GP30Accumulator tankCP1
Safety valve, solarFL4Expansion vessel, solar circuitCM5
Circulation pump, solarGP4Solar panelEP8
Shut-off valveQM43
Shut-off valveQM44Solar control SCU 10EP30
Shut-off valveQM45Control unitEP30-AA25
Non-return valveRM3Temperature sensor, solar panel T1EP30-BT53
Non-return valveRM4Temperature sensor, tank bottom T2EP30-BT54