50 – ENGLISH
Automation lock (ON 4 OFF, default = OFF) (0x9A)
This function can be used to inhibit the automation’s movements.
Function ON = no type of sent command will be performed, with the exception of “High-priority step-by-step”, “Unlock”, “Unlock and close” and
“Unlock and open” commands.
Function OFF = normal operation
Button lock (ON 4 OFF, default = OFF) (0x9C)
This function disables operation of the buttons present on the control unit. This function is particularly useful if children are present
Function ON = the control unit inhibits any command sent from the control unit buttons
Function OFF = normal operation
Internal radio inhibition (ON 4 OFF, default = OFF) (0x9B)
This function can be used to inhibit the operation of the internal radio. This function is particularly useful when using an external receiver with SM con
-
nector (optional accessories) belonging to the OXI, OXIBD, etc. families.
Function ON = disables the operation of the internal receiver
Function OFF = normal operation (integrated radio enabled)
Anti-tamper (ON 4 OFF, default = OFF) (0x9F)
This function can be used to manage the anti-tamper function following a complete closing manoeuvre.
Function ON = once the closed position has been reached, the control unit activates the “anti-tamper” mode designed to hinder potential attempts to
manually open the automation. Whenever any shifting of the carriage in the opening direction is detected, the motor undertakes (automatically) to bring
the automation back into the programmed closing position.
Function OFF = normal operation (anti-tamper mode disabled)
Brief reversal value (0,5 4 5 (s), default = 3 (s)) (0x31)
This function can be used to programme the duration of the brief reversal time that the control unit commands as a safety manoeuvre after an obstacle
is detected or a “Stop” command is sent.
Maximum Work Time (10 4 250 (s), default = 120 (s)) (0xA7)
This function can be used to dene the maximum duration allotted to each manoeuvre. Once this time has elapsed, the control unit performs a STOP
automatically by stopping the current manoeuvre. This function is particularly useful for safeguarding the integrity of the electrical motor.
Electric lock time (0,1 4 10 (s), default = 2 (s)) (0x5A)
This parameter can be used to programme in the control unit the desired time that must elapse between the end of a closing manoeuvre and the start
of an opening manoeuvre.
Suction cup time (0,1 4 10 (s), default = 2 (s)) (0x5C)
This parameter can be used to programme in the control unit the desired time that must elapse between the end of a closing manoeuvre and the start
of an opening manoeuvre, when the suction cup is detached.
Courtesy light time (0 4 240 (s), default = 60 (s)) (0x5B)
This parameter can be used to programme the desired duration for which the courtesy light remains lit at the end of each manoeuvre or following a
“Courtesy light timer” command