Surge (0x8F)
a
After any change made within this menu, the control unit must restart the Automatic Force Search procedure (refer to the
Automatic force search” paragraph).
Active (ON
4
OFF, default = OFF)
This function is useful in the presence of high static friction (for example, snow or ice obstructing the automation) as it allows for momentarily increasing
(see surge time) the speed and force used in the initial phase of a manoeuvre
Function ON = the values assigned to the functions associated with motor force and speed are (momentarily) increased to give the motor more power
during the initial phase of a manoeuvre
Function OFF = normal operation
Surge time (1
4
10 (s), default = 3s)
This function can be used to programme the duration of the motor’s initial surge
a
WARNING! The function is only effective if the “spurge” function is set to ON.
Pre-ashing (0x93)
Active (ON
4
OFF, default = OFF)
This function can be used to generate a pre-ash before the start of each manoeuvre to signal in advance a danger situation. The pre-ashing times can
be congured for each manoeuvre direction
Function ON = activate the pre-ashing time between activation of the warning light and the start of an opening or closing manoeuvre
Function OFF = the warning light starts ashing when the manoeuvre starts
Opening time (1
4
10 (s), default = 3s)
This function can be used to programme the ashing time that signals the imminent start of an opening manoeuvre; it is associated with the “pre-ash
-
ing” function.
Closing time (1
4
10 (s), default = 3s)
This function can be used to programme the ashing time that signals the imminent start of the closing manoeuvre; it is associated with the “pre-ashing”
function.
Stand-by (0x8B)
Active (ON
4
OFF, default = OFF)
This function can be used to reduce electrical consumption to the maximum as, after the “stand-by time” at the end of each manoeuvre, the outputs,
internal peripherals and status LEDs will be switched off.
Function ON = Activates the stand-by function according to the prole chosen on “Mode”. This function is particularly useful in case of battery-powered
operation
Function OFF = normal operation of the automation
Mode (safety devices
4
BlueBus
4
all, all except Wi-Fi, default = safety devices)
The stand-by function has 4 operating modes:
safety devices – The control unit switches off the BlueBus photocell transmitters and all LEDs, except for the BlueBus LED, which will ash
more slowly instead.
BlueBus The control unit switches off the BlueBus output (the devices) and all LEDs, except for the BlueBus LED, which will ash more
slowly instead.
all – The control unit switches off: the BlueBus output (the devices), the control unit outputs (and the outputs of any expansion modules), the
12 V services voltage, the Wi-Fi module (where present) and all the LEDs, except for the BlueBus LED which will ash more slowly instead.
all except Wi-Fi – The control unit switches off: the BlueBus output (the devices), the control unit outputs (and the outputs of any expansion
modules), the 12 V services voltage, and all the LEDs, except for the BlueBus LED which will instead ash more slowly. In this mode, the
integrated Wi-Fi module is not switched off!
a
WARNING! When the control unit receives any movement command, it restores normal operation. At the end of the manoeu-
vre, if the function is ON, the control unit will reactivate the Stand-by mode.
Stand-by time (0
4
250 (s), default = 60s)
This function can be used to programme the time between the end of a manoeuvre and the start of the “stand-by” function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice SPIDER Series and is the answer not in the manual?

Nice SPIDER Series Specifications

General IconGeneral
BrandNice
ModelSPIDER Series
CategoryDoor Opening System
LanguageEnglish

Related product manuals