www.usmotors.com
ID300/302 Integrated Motor Drive | Troubleshooting Guide
47
Incident Possible Cause Remedy
Motor does
not start
At no load
Mechanical seizing
Whenswitchedo󰀨:
Check that rotation of the shaft is not locked.
Broken power supply line Check the fuses, electrical protection.
Thermal protection Check for motor OL .
On load
Phase Imbalance
Whenswitchedo󰀨:
Check the resistance and continuity of the windings.
Check the electrical protection.
Drive Check the settings.
Thermal protection Check for motor OL .