10 Maintenance
• All work relating to installation, commissioning, and maintenance must be carried out by
experienced,qualiedpersonnel.Beforecarryingoutanywork,disconnectandlockthe
ID300/302 power supply circuit and wait 10 minutes for the capacitors to discharge.
10.1 Checks After Start-Up
After approximately 50 hours of operation, verify that the screws to the motor and the coupling device
are still tight. In the case of chain or belt transmission, verify that the tension is correctly adjusted.
10.2 Cleaning
To ensure that the machine operates correctly, remove any dust or foreign bodies which might clog the
motorcovergrille(anddrivefangrille,ifpresent),andthemotor/drivehousingns.
• Before carrying out any cleaning operation, verify that the motor is completely sealed (Terminal
box, drain holes, etc.). Dry cleaning (vacuuming or compressed air) is always preferable to wet
cleaning.
• To avoid introducing dust and particles under the seals, always clean at reduced pressure from
the center of the motor towards the extremities.
•
• DO NOT disassemble the ID300/302 while it is under warranty as this will immediately void the
coverage.
• Certain components which are sensitive to electrostatic discharge may be destroyed just by
touching them. DO NOT leave any metal object in the connection area, as this could cause a
short-circuit.
10.3DrainingOCondensationWater
Temperature variations cause condensation to form inside the motor, which must be removed before it
adverselyaectsmotoroperation.Condensationdrainholeslocatedatthebottomofthemotormustbe
kept clean to maintain the factory warranty.
10.4 Bearings
Thepermanentlygreasedbearingsoerlonggreaselifeandthereforelubricationforthelifetimeofthe
machines. The grease life depends of speed of rotation and ambient temperature.
• For details about preventative and routine maintenance, refer to the relevant documentation.