2.3 Environmental Characteristics
2.4 Electrical Characteristics
2.4.1 General Characteristics
Button Function
Environmental
protection rating
IP55 = ID300
IP54 = motor
Operating ambient air
temperature
-16° C (-26° F) to 40° C (104° F)
Up to 50° C (122° F) with de-rating (current de-rating of 1 % per additional Celsius degree
from 40° C. For more information, contact Nidec Motor Corporation.
Storage and transport
temperature
Storage time is 2 years at temperature between -15° C (-26° F) and 55° C (131° F). As the
drive low voltage capacitors cannot be reformed due to their location, it is recommended
that drives are powered up for a minimum of 1 hour after every
2 years of storage. This process allows the drive to be stored for an additional
2 years.
As a general rule, machines must be stored in a horizontal position, in a dry location
protected from harsh weather conditions, free from vibration, dust and corrosive gases.
At relative humidity levels above 90%, the motor insulation can drop very quickly and
become virtually non-existent at around 100%. The state of the anti-rust protection on
unpainted motor parts should be monitored. During storage, the motor drain plugs must
be removed to allow condensation water to escape. For long storage periods refer to the
motor installation manual.
Ifthestoragelocationissubjecttovibration,trytoreducethee󰀨ectofthisvibrationby
placing the machine on a rubber pad or similar damping material). Turn the rotor a fraction
of a turn once every 2 weeks to prevent the bearing races from becoming marked.
Relative humidity 5 to 90% (non-condensing).
Altitude < 1,000 m (3,300 ft.) without de-rating.
1,000 m to 3,000 m (3,300 ft. to 9,900 ft.) above sea level: de-rate the maximum output
currentfromthespeciedgureby1%per100m(330ft.)above1,000m(3,300ft.).
For example, at 3,000 m (9,900 ft.), the output current of the drive would have to be de-
rated by 20 %. For more information, contact Nidec Motor Corporation.
Pollution Dry, non-conductive pollution only (pollution degree 2 according to IEC 60664-1).
Vibration Meets the requirements of IEC 61800-5-1, Table 27
RoHS Directive Meets EU Directive 2011/65/EU
EMC Conforms to C3 level of EN 61800-3 + A1 (2012) for '58MPl 1ePl@IAr ID300
Conforms to C3 level of EN 61800-3 +A 1 (2012) and EN 61326-3-1
+EN 61000-6-7 for ID302
UL standards Conforms to UL 61800-5-1_1.