www.usmotors.com
ID300/302 Integrated Motor Drive | Overview of the ID300/302 Integrated Motor & Drive
13
2.4.2 ID300 Ratings
Note: The mains current value is a typical value which depends on the source impedance. The higher
the impedance, the lower the current.
Button Function
Maximum supply
imbalance
3 % voltage imbalance between phases
Starts per hour
By electronic control circuit or keypad: unlimited
ByinterruptingtheACsupply:≤20(equallyspaced)
Motor frequency
variation range
From10to150Hzmaximum.Therangecanbedierent,dependingonifa2poleor4pole
motor is utilized. For more information, contact Nidec Motor Corporation.
Eciency NEMAPremiumEcient
Overload 150% of the full rated output current for 60 seconds or 180% for 3 seconds, 10 times per hour
Mains supply voltage
and frequency
200 V drive: 200 V to 230 V ±10 %, 1 phase or 3 phases
400 V drive: 380 V to 480 V ±10 %, 3 phases
Frequency Range: 45 to 66 Hz
Supply ID300 Drive Motor
Voltage Max Input Current
Size ID300K
Output Power
(V) (A) kW HP
230V
1ph / 3ph
4.5
1
12017 0.25 0.33
5.3 12024 0.37 0.5
8.1 12030 0.55 0.75
400V
3ph
1.6 14012 0.25 0.33
2.2 14015 0.37 0.5
2.9 14018 0.55 0.75