  • J
    Jessica SimsSep 18, 2025
    How to fix coverglass is too thick or too thin on Nikon ECLIPSE Si?
    • Y
      youngdianeSep 18, 2025
      If the coverglass is too thick or too thin on your Nikon Microscope, use a coverglass of the specified thickness (0.17 mm).
  • M
    Michael JohnsonAug 25, 2025
    What to do if the fluorescence image is dark on my Nikon Microscope?
    • D
      Douglas GrantAug 25, 2025
      To brighten a dark fluorescence image on your Nikon Microscope, adjust the illumination by rotating the brightness control knob close to the maximum position.
  • A
    Andrew SchneiderAug 25, 2025
    How to fix aperture diaphragm closed too far for image not bright enough on Nikon ECLIPSE Si?
    • G
      Gregory MillerAug 26, 2025
      If your Nikon Microscope image is not bright enough and the aperture diaphragm is closed too far, you should open it properly.
  • R
    Roger MilesAug 26, 2025
    How to fix field diaphragm closed too far for image not bright enough on Nikon ECLIPSE Si?
    • G
      greenejuanAug 27, 2025
      If your Nikon Microscope image is not bright enough and the field diaphragm is closed too far, you should open it properly.
  • C
    Carol PatelSep 18, 2025
    What to do if slide is upside down on Nikon ECLIPSE Si?
    • M
      Mike StephensSep 18, 2025
      If the slide is upside down on your Nikon Microscope, turn over the slide so that the cove glass faces up.
  • N
    Neil BrownSep 23, 2025
    How to display objective information correctly on Nikon Microscope?
    • K
      klynchSep 23, 2025
      If the objective information is not shown on the display, or incorrect information is displayed on your Nikon Microscope, set the information in the SETUP screen.
  • S
    Scott CurtisSep 9, 2025
    How to fix EX filter slider is not at the click position on Nikon ECLIPSE Si?
    • S
      Sean WilliamsSep 9, 2025
      If the EX filter slider on your Nikon Microscope is not at the click position, move the slider until it clicks.
  • B
    Brenda IngramSep 10, 2025
    How to fix BA filter slider is not at the click position on Nikon ECLIPSE Si?
    • M
      Mathew FaulknerSep 10, 2025
      If the BA filter slider on your Nikon Microscope is not at the click position, push in the slider all the way and move the slider until it clicks.
  • Z
    zfowlerSep 3, 2025
    What to do if specimen rises from stage surface on Nikon ECLIPSE Si?
    • E
      Emily GloverSep 3, 2025
      If the specimen rises from the stage surface on your Nikon Microscope, stabilize it using the holder.
  • L
    Larry WelchSep 1, 2025
    What type of immersion oil should I use to prevent fluorescence with Nikon Microscope?
    • J
      jameshansonSep 1, 2025
      If the immersion oil on your Nikon Microscope is emitting fluorescence, use a low-fluorescence oil (Nikon immersion oil) specified by Nikon.

Summary

Safety Precautions

Meaning of Symbols Used on the Product

Explains symbols on the product for user safety.

WARNING and CAUTION Symbols

Defines WARNING and CAUTION symbols used in the manual.

Chapter 2 Microscopy Techniques

2.1 Bright-field Microscopy

Describes the basic observation method using diascopic illumination.

2.2 Phase Contrast Microscopy

Explains the technique for observing unstained, colorless specimens.

2.3 Simple Polarizing Microscopy

Details the method for measuring polarization and refraction states.

2.4 Diascopic Fluorescence Microscopy

Outlines the procedure for observing specimens stained with fluorescent dye.

2.5 Dark-field Microscopy

Describes the technique for observing unstained specimens on a dark background.

Chapter 3 Detailed Explanation

Chapter 4 Assembly

4.1 Configuration Diagrams

Visual representations of how different parts connect for various configurations.

4.2.1 Basic Configuration (for Bright-field Microscopy)

Step-by-step assembly for the primary bright-field microscopy setup.

4.2.2 Configuration for Phase Contrast Microscopy

Instructions for setting up the microscope for phase contrast observation.

Chapter 5 Troubleshooting

5.1 Problems With the Microscope Image

Lists common issues related to image quality and appearance.

5.2 Problems in Operation

Covers operational difficulties such as focusing and image integration.

5.3 Electrical

Addresses issues related to illumination and power supply.