M795E 20.11.NC.1
Upright Microscope
Instructions

Table of Contents

Questions and Answers

  • B
    Brandon SantiagoSep 12, 2025
    What type of slide glass should I use to prevent fluorescence with Nikon Microscope?
    • K
      Krista BurtonSep 12, 2025
      If the slide glass is emitting fluorescence while using your Nikon Microscope, use a non-fluorescent glass slide.
  • V
    Vanessa GardnerSep 12, 2025
    How to put barrier filter in the optical path on Nikon ECLIPSE Si?
    • L
      Lauren GrantSep 12, 2025
      If the barrier filter is not in the optical path of your Nikon Microscope, push in the BA filter slider all the way, bringing the barrier filter into the optical path.
  • B
    Brenda IngramSep 10, 2025
    How to fix BA filter slider is not at the click position on Nikon ECLIPSE Si?
    • M
      Mathew FaulknerSep 10, 2025
      If the BA filter slider on your Nikon Microscope is not at the click position, push in the slider all the way and move the slider until it clicks.
  • S
    Scott CurtisSep 9, 2025
    How to fix EX filter slider is not at the click position on Nikon ECLIPSE Si?
    • S
      Sean WilliamsSep 9, 2025
      If the EX filter slider on your Nikon Microscope is not at the click position, move the slider until it clicks.
  • T
    Tyler CainSep 8, 2025
    What to do if the specimen's phase difference and the Ph objective type are incompatible on Nikon ECLIPSE Si Microscope?
    • J
      Jackson SanfordSep 8, 2025
      If the specimen's phase difference and the Ph objective type are incompatible when using your Nikon Microscope, use an appropriate Ph objective for the specimen.
  • A
    annettehartmanAug 23, 2025
    How to brighten diascopic illumination on Nikon ECLIPSE Si Microscope?
    • K
      kimberly10Aug 23, 2025
      If the diascopic illumination of your Nikon Microscope isn't bright enough, try these steps: First, adjust the illumination by turning the brightness control knob almost to the maximum position. If that doesn't fully resolve the issue, widen the aperture diaphragm to allow more light to pass through.
  • M
    Melissa BautistaSep 6, 2025
    How to fix Ph annular diaphragm of the phase contrast slider and the objective's phase ring image are not at matching positions on Nikon ECLIPSE Si Microscope?
    • J
      Jennifer PatelSep 6, 2025
      If the Ph annular diaphragm of the phase contrast slider and the objective's phase ring image are not at matching positions on your Nikon Microscope, adjust the position of the annular diaphragm.
  • D
    Dawn DaySep 5, 2025
    How to fix Ph annular diaphragm of the phase contrast slider and the Ph code of the objective are incompatible on Nikon ECLIPSE Si?
    • S
      Scott PopeSep 5, 2025
      If the Ph annular diaphragm of the phase contrast slider and the Ph code of the objective are incompatible on your Nikon Microscope, bring a Ph annular diaphragm that has the same code as the objective's Ph code into the optical path.
  • J
    John VincentSep 4, 2025
    How to fix phase contrast slider is not at the click position on Nikon ECLIPSE Si Microscope?
    • T
      Tiffany FordSep 4, 2025
      If the phase contrast slider on your Nikon Microscope is not at the click position, move the slider until it clicks.
  • Z
    zfowlerSep 3, 2025
    What to do if specimen rises from stage surface on Nikon ECLIPSE Si?
    • E
      Emily GloverSep 3, 2025
      If the specimen rises from the stage surface on your Nikon Microscope, stabilize it using the holder.

Summary

Safety Precautions

Meaning of Symbols Used on the Product

Explains symbols on the product for user safety.

WARNING and CAUTION Symbols

Defines WARNING and CAUTION symbols used in the manual.

Chapter 2 Microscopy Techniques

2.1 Bright-field Microscopy

Describes the basic observation method using diascopic illumination.

2.2 Phase Contrast Microscopy

Explains the technique for observing unstained, colorless specimens.

2.3 Simple Polarizing Microscopy

Details the method for measuring polarization and refraction states.

2.4 Diascopic Fluorescence Microscopy

Outlines the procedure for observing specimens stained with fluorescent dye.

2.5 Dark-field Microscopy

Describes the technique for observing unstained specimens on a dark background.

Chapter 3 Detailed Explanation

Chapter 4 Assembly

4.1 Configuration Diagrams

Visual representations of how different parts connect for various configurations.

4.2.1 Basic Configuration (for Bright-field Microscopy)

Step-by-step assembly for the primary bright-field microscopy setup.

4.2.2 Configuration for Phase Contrast Microscopy

Instructions for setting up the microscope for phase contrast observation.

Chapter 5 Troubleshooting

5.1 Problems With the Microscope Image

Lists common issues related to image quality and appearance.

5.2 Problems in Operation

Covers operational difficulties such as focusing and image integration.

5.3 Electrical

Addresses issues related to illumination and power supply.

Chapter 7 Specifications

Nikon ECLIPSE Si Specifications

General IconGeneral
BrandNikon
ModelECLIPSE Si
CategoryMicroscope
LanguageEnglish