Subject to alterations Page 16 of 33
Hotwater
The ”Hotwater” menu enables you to activate and de-activate the electrical heating element in the
hot water tank.
When the heating element is set to ON, a ”w” will occur in the main menu, when the heating ele-
ment is in use.
Options that flash are indicated by ” ”
On the CTS602 control panel, press:
- ESC to return to the previous menu
- p to scroll upwards or downwards through the menus or to
adjust the setting of an activated menu option
- ENTER to activate a menu option
- ENTER to confirm a menu option setting
- OFF switch off the controls
- ON to switch on the controls
HOTWATER
ENTER
EL SUP
ON
EL SUP
”ON”
LEGIONEL
”MON”
ENTER
ENTER
ENTER
ENTER
ENTER
EL SUP
”OFF”
LEGIONEL
OFF
LEGIONEL
”OFF”
A weekday can
be chosen,
where the
hotwater will be
warmed up to
65°C between
01.00 and 06.00
o’clock.
The legionella
fuction is not
active.