126Service Manual – SC6000
40 - Recovery System
Functional Description
The recovery system extracts wastewater from the
oor collected by the squeegee, and deposits it into
the on-board recovery tank.
Vacuum Motor and Recovery Tank
The SC6000 machine has one standard vacuum
motor, plus an optional second vacuum motor for
higher vacuum draw. The vacuum motor generates
airow through the recovery tank and suction
hose to the squeegee. The high velocity air at the
squeegee pulls the wastewater off the oor and up
through the suction hose. As the mixture of air and
water enters the recovery tank, the airow slows
down due to the larger space, and the water drops
out of the airow and into the tank.
The airow passes through an inlet screen to
prevent debris from entering the impeller of the
vacuum motor. The exhaust air is expelled through
ducting in the machine toward the oor so it can be
dispersed without blowing directly on the operator
or the work environment.
Operational Mode Prerequisites
Before the main controller can activate any of the operational modes, it must rst check that the appropriate
prerequisites are met.
• Recovery System Outputs
Vac motors M4 and M5 – Recovery mode (Seat switch closed upon entry) or Squeegee Actuator M6
No recovery system fault (vac motors and squeegee)
Throttle command not equal to zero (and not timed out)
No Estop inhibit
No impact lockout inhibit
No low voltage cut out inhibit (second stage)
No RTF inhibit
Note M5 also requires Vacuum option set to dual in conguration menu
Vac motors M4 and M5 – Wand mode (seat switch open upon entry) or Squeegee Actuator M6
No recovery system fault (vac motors and squeegee)
No Estop inhibit
No impact lockout inhibit
No low voltage cut out inhibit (second stage)
No RTF inhibit
Note M5 also requires Vacuum option set to dual in the conguration menu
Vac 1
Vac 2
Inlet
Outlet

Table of Contents

Other manuals for Nilfisk-Advance SC6000 910C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SC6000 910C and is the answer not in the manual?

Nilfisk-Advance SC6000 910C Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSC6000 910C
CategoryScrubber
LanguageEnglish

Related product manuals