86Service Manual – SC6000 30 - Solution System
Operational Mode Prerequisites
Before the main controller can activate any of the operational modes, it must rst check that the appropriate
prerequisites are met.
• Solution System Outputs
Solution Solenoid L1 –
Scrub system active
No solution solenoid fault
No recovery system fault (vac motors and squeegee)
Throttle command not equal to zero
No Estop inhibit
No impact lockout inhibit
No low voltage cut out inhibit (rst or second stage)
No RTF inhibit
Not turned off with the membrane switch
Not momentarily turned off by the solution timed off paddle switch input
Spray wash pump M10
No spray wash pump M10 fault
Solution tank is not empty
Option (Opt) pump in conguration menu set to “Spray Wash”
• Detergent System outputs
Detergent Pumps M8 and M9
Solution system is active
EcoFlex is enabled in the conguration menu
Not turned off with the control panel detergent switch

Table of Contents