EasyManuals Logo

Nilfisk-Advance SCRUBTEC 344 Series User Manual

Nilfisk-Advance SCRUBTEC 344 Series
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
36Service Manual – SC401, SCRUBTEC 344 04 - Control System - Battery
Machine Settings (continues)
Parameter Description
Range
Resolution
Default
Permissions:
- = not visible
R = read only
W = read & write
Developer
Service/Tech
Production
NPI
Sales
Customer
Softstart Brush (ms) 0-25000 1 800 W R R R - -
Softstop Brush (ms) 0-2500 1 600 W R R R - -
Softstart Vacuum (ms) 0-25000 1 800 W R R R - -
Softstop Vacuum (ms) 0-2500 1 600 W R R R - -
Stopdelay Brush (ms) 0-25000 1 3000 W W R R - -
Stopdelay Vacuum (ms) 0-25000 1 5000 W W R R - -
Brush Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Brush Reduced Voltage (mV) 16500-42000 1 20000 W W R R - -
Brush Voltage Transition time (ms) 0-25000 1 3000 W W R R - -
Reduced Brush Consumption (mA) 0-25500 1 9000 W W R R - -
Vacuum Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Vacuum Reduced Voltage (mV) 16500-42000 1 16500 W W R R - -
Vacuum Voltage Transition time (ms) 0-25000 1 3000 W W R R - -
Solu. Pump Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Det. Pump Target Voltage (mV) 16500-42000 1 28000 W W R R - -
T1on Pump state1 on time (ms) 5-255 1 7 W W R R - -
T1off Pump state1 off time (ms) 0-255 1 33 W W R R - -
T2on Pump state2 on time (ms) 5-255 1 17 W W R R - -
T2off Pump state2 off time (ms) 0-255 1 23 W W R R - -
T3on Pump state3 on time (ms) 5-255 1 40 W W R R - -
T3off Pump state3 off time (ms) 0-255 1 0 W W R R - -
Tm Pump time multiplier 1-255 1 100 W W R R - -
K Solution/Detergent flow ratio (x10) 0-1020 1 268 W W R R - -
%1 Detergent Level 1 percentage (x10) 0-50 1 2 W W R R - -
%2 Detergent Level 2 percentage (x10) 0-50 1 4 W W R R - -
%3 Detergent Level 3 percentage (x10) 0-50 1 8 W W R R - -
%4 Detergent Level 4 percentage (x10) 0-50 1 10 W W R R - -
%5 Detergent Level 5 percentage (x10) 0-50 1 20 W W R R - -
%6 Detergent Level 6 percentage (x10) 0-50 1 30 W W R R - -
--- CALIBRATION PARAMETERS --- W R - - - -
Current sum cutoff (mA) 0-51000 1 50000 W R R R - -
Brush peak current limit (mA) 0-51000 1 40000 W R R R - -
Vacuum peak current limit (mA) 0-51000 1 30000 W R R R - -
Brush continuous current limit (mA) 0-51000 1 25000 W W R R - -
Vacuum continuous current limit (mA) 0-51000 1 16000 W W R R - -
Time for continuous current overload (sec) 0-50 1 30 W W R R - -
Max softstart time multiplier 0-255 1 4 W R R R - -
Wait time softstart current limit (ms) 0-255 1 150 W R R R - -
Current limit during softstart (mA) 0-51000 1 50000 W R R R - -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SCRUBTEC 344 Series and is the answer not in the manual?

Nilfisk-Advance SCRUBTEC 344 Series Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSCRUBTEC 344 Series
CategoryFloor Machine
LanguageEnglish

Related product manuals