• Slowly push the big Allen screw (6)
(6)(6)
(6) back and forth. This will cause the four stripping blades to automatically fit into
the tracks on the guide plate Fig. 9.
• Only now tighten the centering unit.
Fig. 9 Fig. 10
• By rotating the centering scale (17),
(17),(17),
(17), fully open the centering jaws (25)
(25)(25)
(25) and insert the calibrating pin (30)
(30)(30)
(30). Then by
rotating the centering scale (17)
(17)(17)
(17) close the centering jaws as far as the calibrating pin (30)
(30)(30)
(30)
Fig.
10
.
• Loosen screw (19)
(19)(19)
(19) (black)
(black)(black)
(black) and turn the centering scale (17)
(17)(17)
(17) clockwise to diameter
2.0
2.0 2.0
2.0 mm
mmmm
mm. Retighten screw (19)
(19) (19)
(19)
(
((
(black
blackblack
black)
))
) and remove calibrating pin (30)
(30)(30)
(30).
The ST215 is now ready for use.
Dismantling
DismantlingDismantling
Dismantling
the
thethe
the
centering
centering centering
centering unit
unitunit
unit
• Loosen screw (19)
(19)(19)
(19) (black) and remove centering scale (17)
(17) (17)
(17) with a slight turning movement Fig. 11.
• Lift off the O-ring (20)
(20)(20)
(20) and take it out Fig.
12
.
Fig. 11
Fig. 12