Technical data
BDA−N6−ALL−US−1.0www.noax.comPage 22 of 28
7 Technical data
7.1 Weights
Industrial PC − Compact C12: approx. 12.32 lbs / 5.6 kg (depending on integrated options)
Industrial PC − Compact C15: approx. 21.34 lbs / 9.7 kg (depending on integrated options)
Industrial PC − Stainless steel S12: approx. 13.20 lbs / 6.0 kg (depending on integrated options)
Industrial PC − Stainless steel S15: approx. 18.70 lbs / 8.5 kg (depending on integrated options)
Industrial PC − Panel mount P12: approx. 12.75 lbs / 5.8 kg
Industrial PC − Panel mount P15: approx. 15.18 lbs / 6.9 kg
External table power unit including instal-
lation frame:
1.10 lbs / 0.5 kg
External power unit NEMA (IP65)
(optional):
2.64 lbs / 1.2 kg
7.2 Materials
Enclosure C12: Noryl, fiber glass reinforced (impact resistant)
Enclosure C15: Cycoloy C1100 HF
Rear panel C12, C15: Powder−coated aluminum casting
Enclosure and rear panel S12, S15: Stainless steel V2A (1.4301)
Enclosure and rear panel P12, P15: Stainless steel V2A (1.4301)
Touch front: UV resistant, acrylat−coated polyester film (PET) on a glass
base
External power pack Plastic AF−303
External power unit NEMA (IP65)
(optional):
Aluminum coated
7.3 Ambient conditions
Air circulation: Sufficient circulation of the rear panel must be ensured.
Ambient temperature during operation 32F to 113F / 0 to +45° C (depending on the integrated options)
Ambient temperature for storage and
transportation
−4F to 140F / −20 to +60° C
Humidity: 5 − 90% relative humidity not condensing
7.4 External power units
Input voltage 100 − 240 VAC
Input frequency: 50 − 60 Hz
Rated current: max. 1.5 A
Output voltage: 24 V regulated
Output current: ext. power unit 3 A, NEMA (IP65) power unit 3.3 A
Approvalsl: UL, GS, CE, FCC