EasyManua.ls Logo

Nokia 7705 - Support for BFD Failure Action with SR-TE Lsps

Nokia 7705
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPLS and RSVP-TE
110
MPLS Guide
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 18686 AAAB TQZZA
[no] bfd-enable
[no] bfd-template
[no] wait-for-up-timer <seconds>
exit
When S-BFD is configured at the LSP level, separate S-BFD sessions with the same
configuration are enabled on all primary, secondary, and standby paths of the LSP.
Alternatively, S-BFD can be configured on the primary path or secondary path of the
LSP, as follows:
configure>router>mpls>lsp <name> sr-te
primary <name>
bfd
[no] bfd-enable
[no] bfd-template <name>
[no] wait-for-up-timer <seconds>
exit
configure>router>mpls>lsp <name> sr-te
secondary <name>
bfd
[no] bfd-enable
[no] bfd-template <name>
[no] wait-for-up-timer <seconds>
exit
standby
The wait-for-up-timer command only applies if the configured failure action is
failover-or-down. For more information, see Support for BFD Failure Action with
SR-TE LSPs.
3.12.6.2 Support for BFD Failure Action with SR-TE LSPs
S-BFD provides a mechanism to check the data path forwarding for an SR-TE LSP.
If an S-BFD session fails, the LSP can be brought operationally down when the
failure-action command is configured with the failover-or-down option. When the
failure-action command is not configured, an S-BFD failure will only raise a trap.
The failure-action command is available in the following context:
configure>router>mpls
lsp <name> sr-te
bfd
failure-action failover-or-down
no failure-action
The failure-action command is configured at the LSP level. It can be configured
whether S-BFD is applied at the LSP level or the individual path level. The failure-
action command can be configured even if the BFD template is not yet configured.

Table of Contents

Other manuals for Nokia 7705