4.2.7 Changing the Sensitivity of the System
The Sensitivity (Sensi) setting (Section 5.1.1) can be adjusted in both
MANUAL and AUTO modes. Toggle the "SETUP (NO)" switch to view
the current Sensi setting. While viewing this menu, toggle the "+/-"
switch to adjust the value.
A lower number will reduce the system sensitivity and improve stability.
Increasing the number will speed up the response.
Five is the normal setting. At the start of operation, before the sprayer is
warmed up, a lower Sensi setting may be required for stable control. As
the sprayer warms up, increase the Sensi setting up until the performance
reaches an optimum level.
4.2.8 Changing Between SOIL and CROP Mode
The SOIL or CROP mode (Section 5.2) setting can be adjusted in both
MANUAL and AUTO modes. Toggle the "SETUP (NO)" switch twice to
view the current setting. While viewing this menu, use the " +/- " switch to
change between SOIL and CROP mode.
4.2.9 Changing between Inches and Centimeters
The panel can be changed to display either centimeters or inches. Toggle the
"SENSOR DISPLAY" switch until the LCD screen says "MORE ?".
Toggle the "YES" switch once and then toggle the "SENSOR DISPLAY"
switch until the LCD screen displays "OTHER ?". Toggle the "YES"
button and then use the "+/-" switch to change between CM and INCHES
mode.