E A S Y R E M O T E N O R D G A S
USER
8.6 - Setting up outside probe KD value
This setting option is available only
if the outside probe is connected, the
remote control device is set as modu-
lating and the use of the outside probe
for modulation (P04 = 2 or 3) is ena-
bled.
This parameter allows to select a curve
to determine the outside temperature –
computed heating temperature ratio. The
setting range is 0.0 to 3.0. The higher the
set value, the greater the influence of the
outside temperature on the determination
of the set heating temperature.
1. Press key until icon starts
blinking.
2. Turn button to set the value you
want.