Loading...
Installation
A1-32
E 2000 Nordson Corporation
All rights reserved
41-3000V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
9. Remove the required amount of cable insulation and wire insulation
and then secure the cable with a cable strap of the correct size, as
shown in Figure A 1-21. Three different sizes of cable strap are
provided: one is attached to the unit just below the power board and
the other two are included in the ship-with kit.
4130763
1
2
Fig. A 1 -21 Installing the Cable Strap on the Electrical Service Line
1. Electrical service line 2. Cable strap
10. Connect the ground wire of your electrical service line to the ground
terminal below TB1 as shown in Figure A 1-22.
4130765
Fig. A 1-22 Connecting the Ground Wire
Co
n
n
ec
t
i
n
g
E
l
ec
t
r
i
ca
l
Se
r
v
i
ce
(
contd.)