EasyManua.ls Logo

Nordson Coolwave 2610 - DeviceNet Object (03 HEX − 1 Instance)

Nordson Coolwave 2610
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DeviceNet Specifications
10-6
Part 1105120-03
E 2015 Nordson Corporation
DeviceNet Object (03
HEX
1 Instance)
Class Attributes (Instance 0)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
1 Revision UINT 2 Get
Instance Attributes (Instance 1)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
1 Mac ID USINT 63 Get / Set
2 Baud Rate USINT 0 Get / Set
5 Structure of:
Allocation Choice Byte
Master Mac ID
BYTE
USINT
0xFF
0
Get
Get
6 MAC ID Switch Changed
(since last power up)
BOOL 0 Get
7 Baud Rate Switch Changed
(since last power up)
BOOL 0 Get
8 Actual MAC ID Switch Value (099) USINT 63 Get
9 Actual Baud Rate Switch Value (09) USINT 0 Get
Common Services
Service Code
Implemented for
Service NameClass Level Instance Level
0E
HEX
Yes Yes Get_Attribute_Single
10
HEX
No Yes Set_Attribute_Single

Table of Contents