DeviceNet Specifications
10-11
Part 1105120-03
E 2015 Nordson Corporation
Connection Object (05
HEX
2 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
1 Revision UINT 1 Get
Instance Attributes (Instances 1 2)
Attribute
ID
Name
DeviceNet
Data Type
Data Value
Access
Rule
Instance 1 (EM) Instance 2 (Poll)
1 State USINT 0 = NonExistent
3 = Established
5 = Deferred
Delete
0 = NonExistent
1 = Configuring
3 = Established
4 = Timed Out
Get
2 Instance Type USINT 0 1 Get
3 Transport Trigger usint 83
HEX
82
HEX
Get
4 Produced
Connection ID
uint 10xxxxxx011
BIN
xxxxxx
= Node Address
01111xxxxxx
BIN
xxxxxx
= Node Address
Get
5 Consumed
Connection ID
uint 10xxxxxx100
BIN
xxxxxx
= Node Address
10xxxxxx100
BIN
xxxxxx
= Node Address
Get
6 Initial Comm.
Character
USINT 21
HEX
01
HEX
Get
7 Produced
Connection Size
uint 0 – 30 14 / 8 Get
8 Consumed
Connection Size
uint 0 – 30 4 Get
9 Expected Packet
Rate
uint 2000 msec 0 Get / Set
12 Watchdog Timeout
Action
USINT 3 = Deferred
Delete
0 = Timeout Get
13 Produced
Connection Path
Length
UINT 0 6 Get
14 Produced
Connection Path
USINT Array NULL 20h 04h 24h
65h 30h 03h
Get
15 Consumed
Connection Path
Length
UINT 0 6 Get
16 Consumed
Connection Path
USINT Array NULL 20h 04h 24h
70h 30h 03h
Get