Nordson Coolwave 2610 - Lamp Object (64 HEX − 16 Instances)

Nordson Coolwave 2610
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DeviceNet Specifications
10-15
Part 1105120-03
E 2015 Nordson Corporation
Lamp Object (64
HEX
16 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
1 Revision UINT 1 Get
100 System Ready:
0 – Not Ready
1 – Ready
255 – DeviceNet Disabled (not reported over
DeviceNetJ)
USINT 0 Get
101 Faulted Node Bitmap:
Bit 0 – Master
Bit 1 – Slave 1.....Bit 15 – Slave 15
UINT 0 Get
102 Units Present Bitmap:
Bit 0 – Master
Bit 1 – Slave 1.....Bit 15 – Slave 15
UINT 1 Get
103 Master Lamp State
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0 Get
104 Master Lamp Fault
See SDevice Supervisor for bit definitions
UDINT 0 Get
105 Master Light Intensity Level Set (0100%) USINT 0 Get
106 Master Magnetron Power Level Actual (0100%) USINT 0 Get
110 Master Lamp Command:
1 – Off
2 – On
3 – Standby
5 – Reset
USINT 0 Get / Set
111 Light Intensity Command
20100% (0255% accepted)
USINT 0 Get / Set