Exception Detail Alarm / Warning
Both the Exception Detail Alarm and the Exception Detail Warning use the
same 9 byte array.
Table 10-3 Exception Detail Structure Definition
Bytes 18 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Common
Exception
Detail Size
= 2 (2 bytes to follow)
Common
Exception
Detail Byte 0
0 0 0 0 EEPROM
Exception
0 0 0
Common
Exception
Detail Byte 1
0 0 0 0 0 0 0 0
Device
Exception
Detail Size
= 0 (0 bytes to follow)
Manufacturers
Exception
Detail Size
= 4 (4 bytes to follow)
Manufacturers
Exception
Detail Byte 0
Lamp Out Magnetron
Fault
Current
Slave unit
fault
Current
Imbalance
Magnetron
over
current
Filament
Fuse
Magnetron
Fault
Local Net
config
error
Manufacturers
Exception
Detail Byte 1
Power
Regulation
Fault
unassigned Slave Unit
not
present
Magnetron
Voltage
Fault
DeviceNet
Bus OFF
Duplicate
MAC ID
PC Board
hardware
fail
Unassigned
Manufacturers
Exception
Detail Byte 2
HV Cable
unplugged
Lamphead
over temp
MSTOP
open
RF
Detector
Fault
RF
Detector
missing
Power
Unit over
temp
External
Interlock
Low
Lamphead
Pressure
Manufacturers
Exception
Detail Byte 3
Unassigne
d
Unassigne
d
Unassigne
d
Mag
Filament
Open
Phase
Controller
Fault
RF
Detector
Failed
Phase
Control at
Limit
Low
magnetron
current