Operating Parameters
B-2
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
Standard
1 Total Hours with Heaters On (Noneditable)
Description:
A non editable value that indicates the total number of hours that the
heaters have been on.
Value:
9999 (control panel) and 999,999 on the web browser
Resolution:
1 hour
Default Value:
0
Format:
Use:
The display registers up to 9999 hours and then rolls over to 0000. On
the web browser, the register rolls over at 999,999 hours.
2 Fault Log (Noneditable)
Description: Stores a record of the last ten faults.
Value:
Resolution:
Default Value: _-F0 (unused log entry)
Format: F1, F2, F3, and F4
Use: Use the right-display scroll keys to review the log entries for the
last ten faults. Empty log entries are indicated by “_-F0.” Refer
to Monitor the Melter in Section 4, Operation.
3 Change History Log Noneditable)
Description:
Records the last ten changes made to either the set-point temperatures
or the operating parameters.
Value:
Resolution:
Default Value:
P-_ (unused log entry)
Format:
Refer to Section 3, Installation. Review Parameter and Set-point
Temperature Changes.
Use:
Use the right-display key to review the log entries for the last ten changes
that were made to the operating parameters or the set-point
temperatures. Empty log entries are indicated by “P-_.”

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals