Table 3-6 Operating Parameters
Parameter Name Range of Values Default Value
Standard
1 Total Hours with Heaters On (noneditable) 9999 0
2 Fault Log (noneditable) _-F0 (empty)
3 Change History Log (noneditable) P-_ (empty)
4 Ready Delay Time 0 to 60 minutes 0 minutes
7 Motor Off Delay 0 to 360 seconds 0 seconds
8 Automatic Pump On 0 (disabled) or 1 (enabled) 1 (enabled)
12
Change Hose 1 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0 (disabled)
13
Change Hose 2 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0 (disabled)
Temperature Control
20
Temperature Units (degrees _C or _F)
C (degrees Celsius) or F (degrees
Fahrenheit)
C (degrees Celsius)
21 Over Temperature Delta
5 _C (10 _F) to 60 _C (110 _F) 15 _C (25 _F)
22 Under Temperature Delta
5 _C (10 _F) to 60 _C (110 _F) 25 _C (50 _F)
23 Standby Delta
25 _C (50 _F) to 190 _C (350 _F) 50 _C (100 _F)
26 Manual Standby Time 0 to 180 minutes 0 (disabled)
Seven-day Clock
50 Current Day 1 to 7 (1 = Monday)
51 Current Time 0000 to 2359
55 Schedule 1 Heaters On 0000 to 2359 06:00
56 Schedule 1 Heaters Off 0000 to 2359 17:00
57 Schedule 1 Enter Standby 0000 to 2359 —:—
58 Schedule 1 Exit Standby 0000 to 2359 —:—
60 Schedule 2 Heaters On 0000 to 2359 —:—
61 Schedule 2 Heaters Off 0000 to 2359 —:—
62 Schedule 2 Enter Standby 0000 to 2359 —:—
63 Schedule 2 Exit Standby 0000 to 2359 —:—
65 Schedule 3 Heaters On 0000 to 2359 —:—
66 Schedule 3 Heaters Off 0000 to 2359 —:—
67 Schedule 3 Enter Standby 0000 to 2359 —:—
68 Schedule 3 Exit Standby 0000 to 2359 —:—
71 Schedule for Monday 0–7 0
72 Schedule for Tuesday 0–7 0
73 Schedule for Wednesday 0–7 0
74 Schedule for Thursday 0–7 0
75 Schedule for Friday 0–7 0
76 Schedule for Saturday 0–7 0
77 Schedule for Sunday 0–7 0

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals