BCM50 Troubleshooting Guide
Chapter 5
Advanced Troubleshooting
This chapter contains examples of advanced troubleshooting procedures. You must be a system
administrator to perform these procedures.
Navigation
Example 1: Cannot dial out from an analog trunk on page 51
Example 2: Cannot dial out from a SIP or H323 VoIP trunk on page 55
Example 3: IP set is not registering with the BCM50 on page 60
Example 4: Cannot install keycode or invalid keycode application on page 61
Example 5: Cannot dial out from digital trunk on page 62
Example 6: MeetMe Conferencing commands do not work, or conferencing is busy on page
67
Example 1: Cannot dial out from an analog trunk
When you cannot dial out from an analog trunk, you may experience the following problems in
your network:
you are unable to reach a destination number when you dial it
there is no dial tone
instead of a dial tone, you hear a re-order or fast-busy tone
you hear a “wrong number” message from the central office.
Use the following procedure when you cannot dial out from an analog trunk.
Troubleshooting example 1
1 Check that the LED indicators on the BCM50 Chassis and the MBM are solid green.
2 Using an analog test set, verify that a dial tone is present at the MBM termination point.
3 From the Element Manager, select Configuration > System > Keycodes to view the list of
installed features.