8 AFP-200 Instruction PN 15511:F2 10/11/99
• Single standard communication (SLC) loop, meets
NFPA Style 4, 6, or 7 requirements
• 198 intelligent device capacity
• Overall 301 point capability
• Four Notification Appliance Circuits standard
• Optional eight-zone relay module with transmit-
ter
• Optional 911ACDigital Alarm Communicator/
Transmitter
• Optional UDACT Universal Digital Alarm Com-
municator/Transmitter
• LCD-80 liquid crystal display, mounts up to 6,000
feet from panel
• ACS annunciators, including LDM custom
graphic annunciators
• ACM-8R remote relay module, increases point
capacity
• Printer interface
• Real time clock, with European format option
• History file with 650 event capacity
• Intelligent features
• Sensitivity display in percent
• Manual sensitivity adjustment
• Day/Night automatic sensitivity adjustment
• Drift compensation (U.S. patent pending)
• Auto detector test (meets NFPA 72E)
• Maintenance Alert
• Pre-Alarm (AWACS – 2 levels)
• LED blink control
• Releasing features
• Four independent hazards
• Cross zone (three methods)
• Delay timer
• Soak timer
• Abort – four options
• Manual release
• Waterflow (non-silenceable) selection per
module point
• Supervisory selection per point with separate
LED
• Alarm Verification
• Walk Test
• Positive alarm sequence (PAS) pre-signal per
NFPA 72-1993
• Silence Inhibit timer option
• Auto silence timer option
• March time/temporal code
• Two-stage option for Canada
• California code
• Tornado warning code
• Remote Ack/Silence/Reset/Drill via MMX
Monitor Modules
• Automatic time control functions, with holi-
day exceptions
• Autoprogram (learn mode) reduces installation
time
• Password- and key-protected nonvolatile mem-
ory.
• Programmable from a PC using the PK-200
programming utility
• Rapid poll algorithm for manual stations (U.S.
patent pending)
• Operates up to 1,000 ft. with untwisted,
unshielded wire (U.S. Patent 5,210,523)
• Operates sounder base on Action Pre-Alarm
level with general evacuation on alarm level.
• Burglar alarm point option.
• Critical process monitoring
• Read status on program via modem using dial-
up phone lines.
• Marine cabinet option (CAB-AM)
1.4 AFP-200 Features
Note: Unless otherwise notated, general terms are used throughout this manual to reference the specific part
numbers shown in the table below:
mreTlareneGmreTlareneG
mreTlareneG
mreTlareneGmreTlareneG)s(rebmuNtraPcificepS)s(rebmuNtraPcificepS
)s(rebmuNtraPcificepS
)s(rebmuNtraPcificepS)s(rebmuNtraPcificepS
XMC2-XMCro1-XMC
TRC2-TRC
XMM2-XMMro,1-XMM,101-XMM
NRP4-NRP