Intelligent Fire Panel
AFP-100/AFP-100E
Instruction Manual
Document 51010
02/06/2002 Rev:
C1
PN 51010:C1 ECN 01-552
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Notifier AFP-100 and is the answer not in the manual?

Notifier AFP-100 Specifications

General IconGeneral
TypeFire Alarm Control Panel
ManufacturerNotifier
ModelAFP-100
Alarm Current2.5A
Operating Temperature32°F to 120°F (0°C to 49°C)
Relative Humidity10% to 93% non-condensing
NAC Outputs4
Power Supply120 VAC, 60 Hz, 3.0 A or 220/240 VAC, 50 Hz, 1.5 A
Battery Backup24V DC
Weight15 lbs
Communication PortsRS-232, RS-485

Summary

1. Product Description

2. Installation

Checklist

A comprehensive checklist for installing, wiring, and testing the AFP-100 system.

Power Connections

Details on making AC power connections and earth ground connections.

UL Power-limited Wiring Requirements

General guidelines for separating and routing power-limited and nonpower-limited wiring.

3. Programming

Enter Programming Mode

Procedure to access the control panel's programming mode via the ENTER key.

Passwords

Information on factory set passwords and how they control access to programming levels.

Program Change – Level One

Details on Level One programming functions like Clear, Autoprogram, and New Detectors.

New Detectors

Procedure for programming new detectors, including ADJ, NOUN, and zone assignments.

Monitor Modules

Procedure for programming monitor modules, including Type Code selection and assignments.

Control Modules

Procedure for programming control modules, including Type Code selection and zone assignments.

Point Edit

Allows editing of device descriptor screens for addressable points.

System Edit

Enables modification of system function options like Alarm Verification and SLC style.

Password Change

Procedure for changing the system's Level 1 and Level 2 programming passwords.

Load

Function for transferring the application database to/from a Windows-based computer.

Program Change – Level Two

Details on Level Two functions including Disable, Clear History, Walktest, Time/Date, and Check.

Walktest and Conditions

Procedure for performing system walktests and identifying shorted/alarm and open conditions.

4. Operation

Trouble Operation

Details how the system indicates and handles trouble conditions for various devices.

Alarm Operation

Describes how the system indicates and responds to alarm conditions.

Read Status

Explains how to access and display device status, history, and program information.

Appendix A: Power Supply Calculations

The AC Branch Circuit

Requirements for the dedicated AC branch circuit needed for the fire alarm system.

The Main Power Supply

Information on the AFP-100's power supply capabilities for operating the system.

Calculating the Battery Capacity

Table and notes for determining the required battery capacity for system standby.

Appendix B: Electrical Specifications

Electrical Specifications Overview

Details AC power, battery, SLC, NAC, and relay specifications.

Appendix C: Software Zones

Sample Programming Sheets

Templates for documenting detector zone assignments during programming.

MONITOR/CONTROL MODULE ZONE ASSIGNMENT

Template for documenting monitor/control module zone assignments.

Appendix D: NFPA Standard-Specific Requirements

NFPA Standard-Specific Requirements Overview

Details minimum and additional NFPA 72 requirements for system service types.