5. Voice Alarm Systems Selecting AMG Tones and Messages
30 AFP-300/AFP-400 Operations PN 50260:C1 05/22/97
AMG-1 and AMG-E Tone/Message Selections (AMG-1 SW2=On) Table 24 lists
the tone and message selections available when SW2 rocker switch 2 (Tone/Message
Switch) is On.
Table 24 Setting AMG Tones and Messages (AMG-1 SW2=On)
1. You can manually select MPS-400 Notification Appliance Circuit 1 (NAC1) with an
ACM-16AT to produce a desired tone or it can be activated through Control-by-
Event by a non-alarm input.
2. If selecting a VROM or VRAM that is not installed, a trouble will be generated at
the AMG-1 and the AMG-1 generates the 1 kHz default tone.
3. Boston Code (order VROM-109, which must be installed in VROM-B position) –
900 Hz alert tone pulsed to produce one round of code 4 at approximately one
second intervals, followed by female voice message:
Attention please. The signal tone you have just heard indicates a report of an emergency in this
building. If your floor evacuation signal sounds after this message, walk to the nearest stairway and leave
the floor. While the report is being verified, occupants on other floors should await further instructions.”
This message repeats. The evacuation signal is a slow-whoop tone—an ascending
tone that starts at approximately 600 Hz and ends at approx.1100 Hz—with a
duration of approximately 3.5 seconds and an interruption between tones of
approximately 0.5 second.
AMG-1 SW2 Rocker
Switches
System
Status
NAC 1 (B01)
Condition
Audio Tone or Message
S6 S7 S8
X X X No Alarm Off Standby
Off
Off
Off
Off
Off
Off
No Alarm
Alarm
On
Off
Horn1000 Hz 1/2 sec on, 1/2 sec off for
5 min. then slow whoop
Off
Off
Off
Off
Off
Off
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Horn
20 ppm for 5 min., then 120 ppm
120 ppm (March Time)
Off
Off
Off
On
On
On
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
VROM-B
444, pause, VROM-A
Boston Code
Off
Off
Off
On
On
On
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
VROM-B
Fast whoop
3 fast whoops, pause, VROM-A
On
On
On
Off
Off
Off
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
Beep
Fast whoop
3 fast whoops, pause, VROM-A and
VROM-B
On
On
On
Off
Off
Off
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Beep
3 slow whoops, pause, VROM-A
3 slow whoops, pause, VROM-A and
VROM-B
On
On
On
On
On
On
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
Wail
3 hi-low tones, pause, VROM-A
3 hi-low, pause, VROM-A and VROM-B
On
On
On
On
On
On
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Hi-low
20 ppm (Two-Stage)
3 Slow whoops, pause, VROM-A
X = Indicates that Switch or Control Point can be On or Off.
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Other manuals for Notifier AFP-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier AFP-400 and is the answer not in the manual?

Notifier AFP-400 Specifications

General IconGeneral
BrandNotifier
ModelAFP-400
CategoryControl Panel
LanguageEnglish

Related product manuals