EasyManua.ls Logo

Notifier CFP-600-E User Manual

Notifier CFP-600-E
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and Operating Manual
Document:
M-131.1-CFP600-ENG
Issue :
07/1999
Rev.:
B.1
CFP-600-E
12-Zone Conventional
Control Panel
NOTIFIER ITALIA
a Pittway Company
Complies with EN54.2
Question and Answer IconNeed help?

Do you have a question about the Notifier CFP-600-E and is the answer not in the manual?

Notifier CFP-600-E Specifications

General IconGeneral
BrandNotifier
ModelCFP-600-E
CategoryControl Panel
LanguageEnglish

Summary

Installation Precautions

General Warnings and Cautions

Covers overall safety warnings and cautions for installation.

General Installation Practices

Details wire sizing, power disconnection, enclosure modification, and static protection.

System Limitations and Maintenance

Outlines smoke detector limits, power failure effects, equipment compatibility, and maintenance.

Control Functions and Acknowledgement

Control Silence, Reset, and Evacuation

Explains control silence, silenced control reset, and evacuation activation/deactivation.

Alarm and Trouble Reset

Details the process for resetting all alarms and troubles in the system.

User Access and Menus

Entering Passwords

Explains password entry mechanism and default passwords for system access.

Zone Management

Change Zone Enable/Disable Status

Explains the procedure to enable or disable individual zones.

System Configuration Parameters

Password and Test Menu

Change Level 1 Password

Explains the process for modifying the Level 1 access password.

System Tests and Controls

Select Zone for Walk-Test Mode

Details selecting specific zones for conducting manual detector walk-tests.

Advanced Configuration

Change Level 2 Password

Explains the procedure for modifying the Level 2 access password.

Configuration Menu - Level 4

Introduces the comprehensive set of functions available in Level 4 configuration.

Change Zones Include/Exclude Status

Describes how to include or exclude zones from signaling alarms or troubles.

Logic and Service Configuration

Programming the CBE Equations

Details mapping events to logic zones for activating specific functions.

Zone Settings

Change Zone Parameters

Allows programming zone thresholds, night mode, and reset relay behaviors.

Relay Configuration

Programming Relay Mapping

Maps detecting zones to specific output relays on the optional 16-relay board.

Alarm Timing and Modulation

Change Alarm Time Parameter

Sets parameters for prealarm, alarm, sounder, and walk-test time durations.

Release and Event Logging

Programming Release Zone Mapping

Maps detecting zones to specific release channels on optional boards.

Password Management

Change All Level Passwords

Explains the procedure to modify passwords for all access levels (1 to 4).

Installation Guide

Control Panel Wiring

Wiring Diagram Overview

Presents the main wiring diagram showing all connections for the control panel.

Optional Boards

Release Channel Optional Board

Electrical Features