EasyManuals Logo
Home>Notifier>Control Panel>NFS-3030/E

Notifier NFS-3030/E User Manual

Notifier NFS-3030/E
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
General Information Introduction to the Control Panel
8 NFS-3030 Operating P/N 51344:C 11/4/03
1.3 Introduction to the Control Panel
The NFS-3030 is an intelligent Fire Alarm Control Panel (FACP) with features suitable for most
applications. The CPU-3030 comes with a front display/keypad option, which allows programming
and viewing options at the panel.
There are two basic configuration options for the NFS-3030/E. It can be ordered with:
a front display/keypad, which allows programming and viewing options at the panel, or
no display keypad.
This manual gives instructions using the front display/keypad.
Displayless Mode
When there is no keypad/display at the NFS-3030, the panel is controlled by remote annunciators.
VeriFire™ programming is required. The displayless panel has four buttons on its circuit board that
are service-level switches for local operation should it become necessary. They are the only
buttons, and are clearly marked with ACK for Acknowledge, SIGSIL for Signal Silence, SYSRST
for System Reset, and LAMP TEST. These buttons are mainly for installer use: the operator should
utilize a remote annunciator for these functions, if possible. The status indicator LEDs on the
circuit board are the same as on the display/keypad (refer to "The Display/Keypad" on page 9 of
this manual).
Refer to VeriFire™ Tools or the NCA manual for information on programming without an NFS-
3030 display/keypad.
1.4 Operating Features
•Alarm Verification selection, to reduce unwanted alarms
•Positive Alarm Sequence (PAS) and Presignal per NFPA 72
•Silence Inhibit timer and Auto Silence timer for Notification Appliance Circuits (NACs)
•March time/Temporal code for Panel Circuit modules
•Programmable Signal Silence, System Reset, and Alarm Activate functions through monitor
modules
•Automatic time-of-day and day-of-week control functions, with holiday option
•AWACS (Advanced Warning Addressable Combustion Sensing) with nine field-adjustable
Pre-Alarm levels with programmable Control-By-Event (CBE)
•Operate automatic smoke or heat detector sounder base on action Pre-Alarm level, with
general evacuation on alarm level
•Security alarm point option with separate audible signal code
•Centralized voice paging and audible alarm signaling options
•Programmable Control-By-Event control of outputs from individual alarm or supervisory
addressable devices
•Networks with other FACPs and equipment for large applications
•Automatic detector sensitivity adjustments based on programmable building occupancy
schedules
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Other manuals for Notifier NFS-3030/E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS-3030/E and is the answer not in the manual?

Notifier NFS-3030/E Specifications

General IconGeneral
BrandNotifier
ModelNFS-3030/E
CategoryControl Panel
LanguageEnglish

Related product manuals