OPERATION 8. HOW TO USE APPLIED FUNCTIONS (PARAMETER)
8-2. Selection of the Program No. Input Method
This method is available for VS-5FD, VS-5FD-1, VS-5FX, and VS-5FX-1.
Selects the input format of the program number to be operated.
● Parameter list
No. Name Description Setting range
Initial
value
setting procedure
97
Program No.
input format
Selects the input format of
the program number to be
1: By external connector input
2: By serial communication
0
8-1-1
8-1-2
When the Program No. is changed by an external (BCD output connector), the timing will be as shown below.
Turns OFF the power supply
2 0μs
The switch output turns ON/OFF
according to the setting values.
Ex. Turns ON the power supply and
the program No.2 is selected.
Program No. input
1
4
ready output
output
ng pulse output
CAUTION
When the program No. is changed, the system ready signal turns OFF approximately 0.5 seconds.
The switch output (Arbitrary pulse output) and timing pulse are “HOLD” status during the time.
Use care when changing the program No..
CAUTION
When “2” or “3” is selected at the parameter No. 85 (Protocol), parameter No. 97 (Program No.
input format) is disabled and the selecting program No. is fixed to ”0”
POINT
In the case of selecting “0: By panel key input” and setting the password, the password must be input when
changing the program No.. Refer to “ APPENDIX 1” for the password.