6 - 4 en-938821/2
Some choices depend on data bits (for example: general feed authorisation) to be viewed on the "PLC MEMORY"
page; each data bit represented by its mnemonic (for example: FEED).
A mnemonic corresponds to a bit designated by a variable that depends on the PLC programming language used (in
Ladder language, AUTAV corresponds to bit %W4.0. See Appendix D for the corresponding mnemonics). This
address is entered to view the bit value on the "PLC MEMORY" page (in Ladder language, view of the byte containing
the bit: %W4.0 is bit 1 of byte %W4.B).