EasyManuals Logo

NUM 1020 M User Manual

NUM 1020 M
388 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #281 background imageLoading...
Page #281 background image
en-938821/2 8 - 21
8
Operator-Accessible Maintenance
Exit from the utility by selecting a display page.
Display of the message:
WARNING! LOADING REQUIRES A STOP
OK? (YES/NO)
Incidents
The data transmitted are not coherent
Display of the message:
LOAD ERROR
Repeat the data restore procedure.
8.5.3 Check of Machine Data Backup
Requirements
Peripheral ready to send the backed-up data (See peripheral manual and 8.5).
"MACHINE BACKUP" menu displayed (See 8.5).
Actions
Select "COMPARE".
@
2
Display of the "CNC DATA COMPARE" page and the message:
STORAGE UNIT READY?
OK? (YES/NO)
Confirm data comparison.
Y
Initiate data transfer by the peripheral.
Display of the message:
RUNNING
When comparison is completed, display of the message:
VERIFY COMPLETED
Exit from the utility by selecting a display page.
Incidents
The backed-up data are not coherent
Display of the message:
VERIFY ERROR
Repeat data backup (See 8.5.1).