8.8.7 Unloading Programmes from a Protected Zone and Checking Them
The purpose of unloading is to save the programmes on a storage medium:
- individually or globally to reload them in other systems (this operation requires entry of the password for the zone)
- globally used as a backup copy of all the protected area on a single system (the backup is carried out without
entering the password but requires entry of the system job reference).
Unloading also allows a check of the conformity of the programmes on backup with those in the protected area.
Unloading is performed in encrypted binary form, making it impossible to read backed-up programmes.
Requirements
"RESIDENT MACROS" menu displayed (See 8.8).
Actions
Select "UNLOAD/VERIFY".
%
5
Display of the "UNLOAD FROM PROTECTED AREA" menu.
. . / . . EXIT
UNLOAD FROM PROTECTED AREA
> 1 ZONE 1 (END USER)
2 ZONE 2 (OEM)
3 ZONE 3 (NUM)
?
Select "ZONE 1 (END USER)".
!
1
Display of the "ZONE 1 (END USER)" page and the dialogue line:
(&1%% / %* / %..) [> &1%
Exit from the procedure
Return to the "RESIDENT MACROS" menu".
EXIT