8 - 48 en-938821/2
Display of the "LOAD IN PROTECTED AREA" page:
. . / . . EXIT
LOAD IN PROTECTED AREA
LOAD
CURRENT DATA WILL BE DESTROYED
WARNING! SHUT DOWN THE POWER. READY?
? (Y,N)
Confirm loading.
Y
Initiate the transmission of data by the peripheral.
The name of the memory zone for the data loaded is displayed in the title bar (e.g. "ZONE 1 (END USER)").
If only one programme is loaded, the programme number is displayed, e.g.:
PROGRAMME No.: %1.2
Display of the message:
WRITING IN PROGRESS
At the end of transmission, display of the message:
BACKUP LOADED
Return to the "RESIDENT MACROS" menu.
EXIT
Incidents
Not enough memory in the protected area to copy the programme(s)
Display of the message:
MEMORY ZONE FULL
If required, repeat the operation with a smaller programme.
REMARK The memory size can be increased by machine parameter P95 (See Parameter
Manual) before resuming copy.