Function Summary Tables
en-938821/2 A - 23
A
Parameters Description Value Access by the
or units part programme
E56001 to E56255 Available parameters - 99999999 Read/write
(H of the wear offset table) to 99999999
E57001 to E57255 Tool type 0 to 2 Read/write
E6x000 DAT1 internal unit Read/write
x = axis number (0-8) (+ graphic)
E6x001 DAT2 internal unit Read/write
x = axis number (0-8) (+ graphic)
E6x002 Minimum dynamic travel internal unit Read/write
x = axis number (0-8) (+ graphic)
E6x003 Maximum dynamic travel internal unit Read/write
x = axis number (0-8) (+ graphic)
E6x004 DAT3 (limited to linear axes) internal unit Read/write
x = axis number (0-5) (+ graphic)
E6x005 Shift programmed by G59 internal unit Read/write
x = axis number (0-8) (+ graphic)
E69000 Scaling factor 1/1000 Read/write
(+ graphic)
E69001 Axis inclination on grinding machine (turning) 1/10000 degree Read/write
(+ graphic)
E69002 Wheel inclined on grinding machine (turning) 1/10000 degree Read/write
(+ graphic)
E69003 Axis assignment XYZ axis Read/write
assignment (+ graphic)
E7x000 Position reference internal unit or Read only
x = axis number (0-8) 1/10000 degree
E7x001 Reference on on-the-fly dimension internal unit or Read/write
x = axis number (0-8) measurement 1/10000 degree
E7x002 Minimum static travel internal unit or Read only
x = axis number (0-8) 1/10000 degree
E7x003 Maximum static travel internal unit or Read only
x = axis number (0-8) 1/10000 degree
E7x004 Direction of movement internal unit or Read only
x = axis number (0-8) 1/10000 degree
E7x005 Axis address assignment -1 to 31 Read/write
x = axis number (0-8)
E7x006 Carried axis 0 or 1 Read/write
x = axis number (0-8) (+ graphic)
E7x007 Axes programmed by diameter 0 or 1 Read only
x = axis number (0-8)
E7x100 Interpolator position reference internal unit Read only
x = axis number (0-8)
E7x101 Interpolation speed limiting 0 to 100 Read/write
x = axis number (0-8)