7 - 12 en-938821/2
7.12 Incoherent QVN Sensor Address
Message displayed at initialisation
ERROR: QUESTIONABLE SENSOR NUMBER
CONTINUE (Y/N)?
Comment
A position or speed sensor address is outside the value authorised for parameters P70 and P71 (See Parameter
Manual).
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Correct the faulty address in parameter P70 or P71 (See Parameter Manual).
Reset the system to take the new parameter into account.
7.13 Sensor Declared on QVN Card but Detected on an Axis Card
Message displayed at initialisation
ERROR: SENSOR DECLARED ON QVN CARD BUT
DETECTED ON AN AXIS CARD
CONTINUE (Y/N)?
Comment
A sensor is declared as connected in parameter P70 (See Parameter Manual) but is detected on an axis card.
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Cancel the sensor declaration in parameter P70 (See Parameter Manual).
Reset the system to take the new parameter into account.