8.7 Battery Management Update
The "BATTERY MANAGEMENT" page allows you to:
- see when the batteries were installed
- update the battery replacement date (See 8.1.1.1).
Whenever the system is turned on, the battery replacement date is checked. If the date has elapsed, the system
generates the message "REPLACE SYSTEM BATTERIES".
REMARK Battery management is meaningless if the system time-date is not set.
Requirements
"CN UTILITY" menu displayed (see 8.2.1).
Actions
Select "BATTERY MANAGEMENT".
%
5
Display of the "BATTERY MANAGEMENT" page:
EXIT
Set
BATTERY MANAGEMENT
BATTERIES INSTALLED ON 28 AUG 98
REPLACE BATTERIES ON 15 AUG 02
Select "Set" to update the battery replacement date.
Set
Display of the message:
Has the system date/time been set?
OK? (Yes/No)
If the system date and time are correct, confirm (or refuse) the battery replacement date. If the system time needs
to be set, refer to Section 8.6 (see "Exit from the Procedure" below).
Confirm or refuse the battery replacement setting.
YES
or
No
If you answer Yes, the "BATTERY MANAGEMENT" page is displayed. The dates of battery installation and
replacement are modified (date of entry + 60 months, day rounded off to nearest fortnight). If you answer No, the dates
are unchanged.