7.16 Speed and Position Sensor Declared on Several Axes
Message displayed at initialisation
ERROR: SPEED AND POSITION SENSOR
DECLARED ON SEVERAL AXES
CONTINUE (Y/N)?
Comment
A sensor is declared as position sensor and speed sensor on at least two different axes in parameter P71 (See
Parameter Manual).
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Enter correct sensor addresses in parameter P71 (See Parameter Manual).
Reset the system to take the new parameter into account.
7.17 Position Sensor Not Found on Axis Card and Not Declared as QVN
Sensor
Message displayed at initialisation
ERROR: POSITION SENSOR NOT FOUND ON
AXIS CARD AND NOT DECLARED AS CONNECTED
TO QVN CARD
CONTINUE (Y/N)?
Comment
The system detects a sensor at initialisation, but the sensor is not connected to an axis card and is not declared in
parameter P70 (See Parameter Manual).
This means that the sensor is connected to a QVN card but is not declared as such.
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Declare the sensor in parameter P70 (See Parameter Manual).
Reset the system to take the new parameter into account.