S.Y - Sync-to-
Trigger
The Sync-to-Trigger (SY) parameter allows
the
ability to synchronize various
functional behaviors
of
the
Cyclone
to
the gating
of
notes
on
the keyboard. (This
parameter has no effect
in
Live Trigger Rhythms). For
all
Values, the "Trigger" being
referred to
is
a transition from no notes being held/gated
to
any
notes being held/gated
within the Zone(s).
In
Pulse Rhythm,
if
Link (Li)
is
On, then this definition applies
to
both Zone 1and Zone 2 together; otherwise, each Zone can generate
its
own
independent Trigger. The processing which happens
when
this Trigger
is
received
is
determined
by
the Value
of
Sync-to-Trigger
as
follows:
Display
Meaning
Description
OF
Off
No action results.
CL
Clock
In
Recorded Rhythm,
the
Cyclone re-starts the
timing pattern from the beginning, e.g. Beat
1.
In
Pulse Rhythm, the Cyclone advances
the
internal
Pulse Clock
to
coincide with the Trigger, so that a
Pulse occurs immediately, and notes are generated.
or
Order
In
addition
to
the processing described above for
Clock,
all
Sources are forced
to
begin the next Scan.
CY
Cycle
All
Sources
are
forced
to
restart from the beginning
(including
all
Auto Transpose cycles).
r.S -
Mode
Reset
The Mode Reset (r.S) parameter determines what to do in
the
case where the number of
Source notes to play (as determined by the setting of the Mode parameter) is not zero when the
end of a Scan
is
reached.
Display
Meaning
On
On
OF
Off
Description
the internal counter which keeps track of the number
of
notes remaining
to
play
is
set
to
0, and the next
rhythm trigger
will
staJ1
at
the beginning
of
the
Source note list.
the
Cyclone will loop
to
the beginning
of
the Source
note list (during the same rhythm trigger) and
continue
to
generate notes
until
the
number ofnotes
defined
by
the
Mode
is
satisfied.
i.A -
Invert
Alternate
The Invert Alternate (I.A) parameter changes the way alternating Orders are processed by the
Cyclone when Auto-Transposing.
Display
Meaning
Description
Page
42
Cyclone
Owner's