What to do if OHAUS TP2KS unit will not turn on?
- JJohn PriceAug 5, 2025
If the OHAUS scale does not turn on, the power adapter may not be plugged in or properly connected to the scale. Check the power adapter connections to ensure they are secure.
What to do if OHAUS TP2KS unit will not turn on?
If the OHAUS scale does not turn on, the power adapter may not be plugged in or properly connected to the scale. Check the power adapter connections to ensure they are secure.
What to do if OHAUS Scales readings are unstable?
Unstable readings on the OHAUS scale can be caused by vibration on the table surface. Place the scale on a stable surface or change the averaging level.
Why OHAUS Scales showing incorrect weight reading?
An incorrect weight reading may occur if the OHAUS scale was not re-zeroed before weighing or if the scale is not properly calibrated. Press the TARE button with no weight on the pan, then weigh the item again. If the issue persists, recalibrate the scale correctly.
What to do if OHAUS TP2KS Scales displays random segments or locks up?
If the OHAUS scale displays random segments or the display locks up, it could be due to the microprocessor locking up. Turn the scale off, and then turn it on again. If the condition persists, the unit requires servicing.
Why OHAUS TP2KS Scales RS232 interface not working?
If the RS232 interface is not working, the print menu settings might not be properly set up, or there may be an issue with the cable connections. Verify that the interface settings in the Print menu correspond to those of the peripheral device. Also, check the cable connections to ensure they are secure.
How to store menu settings or changes on OHAUS Scales?
To store menu settings or changes on the OHAUS scale, you MUST use the End function to exit the menus and save the settings.
Why OHAUS Scales cannot display weight in desired unit or access desired weighing mode?
If the OHAUS scale cannot display weight in the desired unit or access the desired weighing mode, it is possible that the desired unit/mode is not set to ON in the Unit Selection of the Setup menu. See Unit Selection section of Setup menu.
Capacity | 2000 g |
---|---|
Readability | 0.1 g |
Power Supply | AC adapter |
Units | g, oz, lb |
Tare Range | Full capacity |
Operating Temperature | 10°C – 40°C |
Steps for turning the balance on, including display checks and initial indicators.
Step-by-step guide for measuring the weight of an object on the pan.
How to use the tare function to zero out the weight of a container.
Detailed instructions on how to count items using the balance's parts counting mode.
Guide to using the percent weighing mode to determine sample percentages.
Overview of the Calibration Menu's purpose for span and linearity adjustments.
Overview of the User Menu for adapting the balance to environmental conditions.
Overview of the Setup Menu for enabling/disabling balance features and parameters.
Overview of the Print Menu for configuring RS232 interface and print functions.
Step-by-step guide to calibrate the balance's weighing range.
Step-by-step guide to minimize deviation in displayed weights.
Procedure to restore all User menu selections to their original factory settings.
Procedure to restore all Setup menu selections to their original factory settings.
How to enable or disable weighing units and operating modes for the balance.
Procedure to restore all RS232 menu selections to original factory settings.
Table detailing ASCII commands for controlling balance functions via RS232.
Guide to diagnosing and resolving common balance problems and symptoms.
Explanation of various error codes and their suggested remedies.