10.4.3 Sensor Application 1/2
This option allows you to choose which sensor is used to control the heating
system.
Floor: With this setting, the floor sensor controls the heating system.
Room/Floor Protection: With this setting, the room sensor controls the
heating system while the floor sensor limits heating according to
the temperature limits set under Menu/Installer Settings/Floor
Protection.
Room: With this setting, the room sensor built into the thermostat controls
the heating system.
Note! Floor Protection is not active while using the Sensor Application
Room”.
Note that certain menu options will be grayed out and inaccessible as
they are only applicable with the floor sensor.
Floor limit temperatures are set under Menu/Installer Settings/Floor Protection.
Note that changes made under “Sensor Application” do not influence the “Floor
Protection” settings.
>
<