42113901TH01 Rev.3 59 /
Oki Data CONFIDENTIAL
3.3.3 Pull-up Roller Assy
(1) Open the access cover 1.
(2) Lift up the sheet guide Assy 4 to remove.
(3) Tilting the pull-up roller Assy 2 toward the front, remove from the shaft of platen Assy
3.
(4) To install, follow the removal steps in the reverse order.
4
3
2