42113901TH01 Rev.3 82 /
Oki Data CONFIDENTIAL
ItemNo. Specification Drawing Adjustment method
Gap between the con-
tact and the monitor
0.3mm or more Confirm followings.
Make sure that the
gap between the con-
tact and the motor
PCB is 0.3 mm or
more.
At the time of printing
test, make sure that
the contact touches
the motor PCB and it
becomes reduced
speed mode when the
adjust lever is set to
range 2 and 4.
Touching
Contact
Motor PCB
Adjust lever
0.3mm
or more

Table of Contents