MAESTRO PRO INVERTER
ENGLISH
EN - 11
2.2- Sizeandspecicationsoftheroominwhichtoinstalltheairconditioner
• Beforeinstallingtheairconditioner,itisessentialtomakeanaccuratecalculationoftheheatloadin
summer (and cold load in winter for models with heating pump) at the site of installation.
• Themoreaccuratethiscalculationismadethebettertheairconditionerwillbeabletodoitsjob.
• Whenexecutingthecalculations,referdirectlytotheprevailingstandards.
• Forparticularlyimportantapplications,werecommendcontactingexpertheatingengineers.
• Theusershouldtrytolimithighheatloadsasmuchaspossibleasfollows:glassdoorsandwindows
exposedtomanyhoursofsunlightshouldbettedontheinsidewithcurtainsor,evenbetter,onthe
outsidewithcoveringssuchasVenetianblinds,verandahs,refractivelm,etc.).Theair-conditioned
room must remain closed as long as possible.
• Halogenspotlightsorotherelectricalequipmentwithhighpowerconsumptionshouldnotbeusedinthe
room (toasters, steam irons, hot plates for cooking, etc.).
2.3 - CHOOSING THE POSITION OF THE UNIT
To obtain the best operating performance and prevent faults or hazardous conditions, the position of indoor
unit installation must meet the following requirements:
a. Donotexposetheappliancetoheatorsteamsources(g.3).
b. Make sure that the space to the right and left is at least 60 mm (2,4”) and space above the unit is at least
80mm(3,2”).(g.2).
c. Theheightoftheunit’sloweredgefromtheoorshouldbeatleast100mm(4”)ifxedtothewallin
thelowestposition.Ifxedtothewallinthehighestposition,itshouldbeatleast80mm(3,2”)fromthe
ceiling(g.2).
d. Thewallwheretheindoorunitistobexed,mustbestable,strongandsuitabletosupporttheweight.
e. It must be possible to leave room around the unit for any maintenance operations that may be necessary.
f. Nothing should be in the way of the air that needs to circulate both on the top air-intake (curtains, plants,
furniture) and at the front where the air exits. This could cause air swirls that would inhibit the working
efciencyoftheunit(g.3).
g. Donotspraywaterorotherliquidsofanykinddirectlyontheunit(g.3).
h. Theappliancemustnotbepositionedsothattheairowisdirecteddirectlytowardsnearbypeople(g.
3).
i. Neverforcetheopeningoftheairowap(g.3).
l. Donotplacebottles,cans,clothes,owersoranyotherobjectontheairsuctiongrille(g.3).
m. Do not install the air conditioner directly on another household appliance (TV, radio, fridge, etc.), or on
aheatsource(g.3).
The air conditioner must be installed on a wall that communicates with the outside
After determining the best place for installation as described above, check for
the absence of other structures or systems (beams, piers, pipes, wires, etc.) at
the points where the holes are to be drilled, which would prevent drilling the
holes required to install the unit.
Check again to make sure there are no obstacles to air circulation through the
holes to be drilled due to plants and their leaves, slats or panelling, blinds, grat-
ings or grids too dense, etc.).