• This operation must be performed only by the installer or any similarly qual-
ied personnel and in compliance to the current national regulations.
• To prevent the risk of an electric shock it is mandatory to switch off the main
switch before performing the electrical connections or any maintenance op-
eration to the appliances.
To replace the power cord, proceed as follows:
a. Raisetheairsuctiongrille(3)andremovethetwoscrews(3a)(g.28).
b. Extracttheright(releaseusingascrewdriver)andleft(1a)doorsofthefrontcover,thenrotatetheap
(1)andremovethethreescrews(1b)andthetwoscrews(1c)(g.29).
c. Removethefrontcover(g.30).
d.
Unscrewthetwoxingscrews(X2)toremovethefrontcoveroftheswitchgear(X1)(g.31)
.
e.
Unscrewthetwoxingscrews
(X4)
to remove the top cover of the
switchgear
(X3)(g.32).
f. Extract the switch towards the exterior of the
switchgear
(g.34-A).
g. Unscrewcableclippingclamp(J1)(g.33).
h.
Unscrew the cables locking screws of the terminal board
(J2)(g.33)
i. Extract the old cable and insert the new one by following the same path.
l. Lock the three poles of the cable in the
terminal board
(J2)andtightenthescrews(g.34).
m. Lockthecablewiththeclamp(J1)(g.34).
n. Close the
switchgear
.
o. Reassemble the front cover of the machine.
This operation must be performed by specialized personnel possessing the requirements indicated
by law.
2.5 - TOP/BOTTOM INSTALLATION CONFIGURATION
Theunitcanbeinstalledbothinthelowerpart(adjacenttotheoor)andintheupperpart(adjacenttothe
ceiling) of the wall.
Dependingoninstallation(ceilingoroor)itissufcienttochangetheelectroniccongurationsoastoopti-
mizetheapertureanglesoftheairoutletap.
2.5.1-Electroniccongurationforlowerorupperwallinstallations
Workasfollows(seeg.B):
a. Insert the plug in the power socket to power the air conditioner, then
make sure it is switched to stand-by mode.
b. Press the key MODE for more than 10 seconds on the
control panel, until an acoustic signal is emitted.
c. The display shows parameter .
d. Release the key MODE and press it again.
e. Thedisplayshowsconguration
(ceiling installation)
or
(oorinstallation).
f. Press keys + or -toselectthedesiredconguration.
g. Press MODEtoconrm.
h. Press the key
toexitfromtheconguration.