4.3.2 - Functional aspects not to be mistaken for anomalies
The following events may occur during normal operation:
a. The compressor does not start up again immediately after a stop (it takes about three minutes
to start again).
- In the operating logic of the appliance a delay between a compressor stop and its successive restart
has been included, so that the compressor itself is protected against activations that are too frequent.
b. Duringtheheatingoperationoftheheatpumpappliances,theowofhotairmayoccursome
minutes after activation of the compressor.
- Shouldthefanstartatthesametimeasthecompressor,fortherstfewminutesitwouldemitcold
air into the room (and this could bother the occupants) since the unit has not yet reached steady
running conditions.
4.3.3 - Console alarms
If one of the following alarms on the display persists for more than three minutes, please contact an Olimpia’s
assistance centre.
ALARM DESCRIPTION
DISPLAY ALARM
CODE
External air temperature probe faulty 1
Condenser temperature probe faulty 2
Inlet temperature probe faulty 3
Compressor current protection 4
Communication error 5
Power line overcurrent 6
Compressor current protection not suitable 7
Power board DC voltage problem 8
Current anomaly 9
Condenser temperature too high 10
UIPM protection 11
EEPROM error 12
Inlet temperature too high 13
Room temperature probe faulty 14
Evaporator temperature probe faulty 15
Evaporator temperature too low 16
Evaporator temperature too high 17
Mains voltage problem 18
Evaporating fan motor failure 19
Water level alarm 20
EEPROM error 21