4-89
Using the Operation Panel
3 Press [OK]. A blinking question mark (?) appears.
4 Press U or V to select Normal, High 1 or High 2.
5 Press [OK].
6 Press [MENU]. The display returns to Ready.
MC (Main charger output setting)
This sets the output of the main charger. When print quality has
deteriorated, the output of the main charger can be changed to restore
print quality.
1 Press Z while >Service > is displayed.
2 Press U or V repeatedly until >>MC appears.
3 Press [OK]. A blinking question mark (?) appears.
4 Press U or V to select 1 to 5.
5 Press [OK].
6 Press [MENU]. The display returns to Ready.
Optional Functions
You can use the optional applications installed on this machine.
Op Functions
See Optional Functions on page A-10.
>>Altitude Adj.
? Normal
Note This menu only appears when the Altitude Adj. (Altitude
adjustment setting) on page 4-88 is set to Normal.
>>MC
? 3